Column Types

Adhorna has a wide range of cylindrical-conical columns based on height, attachment method, and light fixture type considered in the project.

The columns are fabricated from 3 - 14 m. They can be fixed to the ground by anchor plate (called PLA) or by abutment (called EMP). The series which tolerates greater loads is called Turia (TU) and Segura (SE) and those which tolerate less loads are called Guadiana (GU) and Nervión (NE). All have been fabricated according to European standard UNE-EN 40-7 and have their proper EC marking.

Column to abut

To abut

Column with base plate

With base plate

The columns are fabricated from 3 - 14 m. They can be fixed to the ground by anchor plate (called PLA) or by abutment (called EMP). The series which tolerates greater loads is called Turia (TU) and Segura (SE) and those which tolerate less loads are called Guadiana (GU) and Nervión (NE). All have been fabricated according to European standard UNE-EN 40-7 and have their proper EC marking.

Columnas con placa de anclaje (PLA)

Series Turia

Model H (m) d2 (mm) A (mm) B (mm) C (mm) D (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
TU-0300-PLA 3 114 75 200 260 200 15 18 60
TU-0400-PLA 4 132 18
TU-0500-PLA 5 150 23
TU-0600-PLA 6 168 85 300 400 300 38
TU-0700-PLA 7 186 45
TU-0800-PLA 8 204 53
TU-0900-PLA 9 222 64
TU-1000-PLA 10 240 74

Serie Guadiana

Model H (m) d2 (mm) A (mm) B (mm) C (mm) D (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
GU-0300-PLA 3 114 75 200 260 200 15 18 60
GU-0400-PLA 4 132 16
GU-0500-PLA 5 150 21
GU-0600-PLA 6 168 85 300 400 300 33
GU-0700-PLA 7 186 40
GU-0800-PLA 8 204 47
GU-0900-PLA 9 222 57
GU-1000-PLA 10 240 70

Series Segura

Model H (m) d2 (mm) A (mm) B (mm) C (mm) D (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
SE-0300-PLA 3 114 75 200 260 200 19 18 78
SE-0400-PLA 4 150 27
SE-0500-PLA 5 168 85 300 400 300 40
SE-0600-PLA 6 186 48
SE-0700-PLA 7 204 60
SE-0800-PLA 8 222 70
SE-0900-PLA 9 240 79
SE-1000-PLA 10 258 90
SE-1200-PLA 12 294 126
SE-1400-PLA 14 330 425 325 160

Series Nervión

Model H (m) d2 (mm) A (mm) B (mm) C (mm) D (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
NE-0300-PLA 3 114 75 200 260 200 12 18 78
NE-0400-PLA 4 150 29
NE-0500-PLA 5 168 85 300 400 300 37
NE-0600-PLA 6 186 45
NE-0700-PLA 7 204 38
NE-0800-PLA 8 222 46
NE-0900-PLA 9 240 57
NE-1000-PLA 10 258 65
NE-1200-PLA 12 294 87
NE-1400-PLA 14 330 425 325 124

Columns to abut (EMP)

Series Turia

Model H (m) HTM (m) d2 A (mm) B (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
TU-0300-EMP 3 4 132 75 200 17 18 60
TU-0400-EMP 4 5 150 21
TU-0500-EMP 5 6 168 28
TU-0600-EMP 6 7 186 85 300 38
TU-0700-EMP 7 8 204 45
TU-0800-EMP 8 9 222 55
TU-0900-EMP 9 10 240 68
TU-1000-EMP 10 11 258 78

Series Guadiana

Model H (m) HTM (m) d2 A (mm) B (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
GU-0300-EMP 3 4 132 75 200 17 18 60
GU-0400-EMP 4 5 150 19
GU-0500-EMP 5 6 168 25
GU-0600-EMP 6 7 186 85 300 31
GU-0700-EMP 7 8 204 38
GU-0800-EMP 8 9 222 47
GU-0900-EMP 9 10 240 58
GU-1000-EMP 10 11 258 74

Series Segura

Model H (m) HTM (m) d2 A (mm) B (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
SE-0300-EMP 3 4 150 75 200 23 18 78
SE-0400-EMP 4 5 168 32
SE-0500-EMP 5 6 186 85 300 38
SE-0600-EMP 6 7 204 50
SE-0700-EMP 7 8 222 65
SE-0800-EMP 8 9 240 74
SE-0900-EMP 9 10 258 83
SE-1000-EMP 10 11 276 97
SE-1200-EMP 12 13 312 135

Series Nervión

Model H (m) HTM (m) d2 A (mm) B (mm) Approx. weight (kg) Conicity (mm/m) 0 tip (mm)
SE-0300-EMP 3 4 150 75 200 14 18 78
SE-0400-EMP 4 5 168 19
SE-0500-EMP 5 6 186 85 300 25
SE-0600-EMP 6 7 204 30
SE-0700-EMP 7 8 222 36
SE-0800-EMP 8 9 240 47
SE-0900-EMP 9 10 258 59
SE-1000-EMP 10 11 276 67
SE-1200-EMP 12 13 312 91

How to choose the column model?

If you would like us to specify what type of column is most suitable based on the project light fixture, we ask that you fill out this simple questionnaire and by we will email you the proper model with its technical file.

Column model choice questionnaire (tick)

1. Ground mounting system

2. Column height (metres)

3. Choose configuration

4. Light fixture weight

5. Light fixture area

(*) Required fields